FREQUENTLY ASKED QUESTIONS
Please see below for a list of questions answered regarding cross-connection and backflow prevention. If you have any additional questions or require a quote today, feel free to contact us today.
WHAT IS BACKFLOW PREVENTION?
What is Backflow Prevention?
A term used to include all parts of the Plumbing Trade that deal with protection of the Potable Water System, (The Drinking Water System) and includes Cross Connection Control, Backflow Preventers, Installations, Testing, maintenance, Regulations, Bylaws, Surveys and enforcement.
What is Backflow?
In plumbing, the term means the reversal of the normal direction of flow in a piping System. Plumbing systems are designed for the internal liquids to flow in a desired direction, either into AND around a building, (Domestic Potable Water) OR out of a building (Sewage, Wastes or Storm products) and will flow either by force or by gravity. In the Domestic Potable Water System, water is usually under pressure (force) and will flow in the direction from high pressure to low pressure. Under certain physical conditions, water may be forced, persuaded or pulled in the undesirable direction causing Backflow. These conditions are known as Back Siphonage and/or Back Pressure.
What is Back Siphonage?
A condition caused by the loss or reduction of the supply pressure (to atmospheric or below atmospheric pressure) pulling in the wrong direction. This may happen when the city street main breaks or the internal piping system is shut off and cut for service or repairs.
What is Back Pressure?
A condition caused when the system end pressure raises higher than the supply pressure. This can happen by thermal expansion thru a boiler or mechanical means by a pump or high pressure piping systems.
CROSS-CONNECTION QUESTIONS
Is periodic testing required for backflow preventers?
Yes, and this is to ensure that the valve is working properly and is a requirement on many states and cross-connection control programs. Test cocks are provided on the valve for this purpose and manufacturers are required to furnish field testing information.
Should a backflow preventer be installed in the water supply line to each building?
Because of the growing number of serious building backflow cases, many water purveyors are now requiring the installation of approved backflow preventers at water meters. They are also educating the public concerning cross-connections and the danger of backflow into the local water supply. Since water purveyors cannot possibly be responsible for or monitor the use of water within a residence, the requirements for these cross-connection control programs are increasing throughout the country.
What is a cross connection control program?
This is a combined cooperative effort between plumbing and health officials, waterworks companies, property owners and certified testers to establish and administer guidelines for controlling cross-connections and implementing means to ensure their enforcement so that the public potable water supply will be protected both in the city main and within buildings. The elements of a program define the type of protection required and responsibility for the administration and enforcement. Other elements ensure continuing education programs.
What is potentially dangerous about an unprotected sill cock?
The purpose of a sill cock is to permit easy attachment of a hose for outside watering purposes. However, a garden hose can be extremely hazardous because they are left submerged in swimming pools, lay in elevated locations (above the sill cock) watering shrubs, chemical sprayers are attached to hoses for weed-killing, etc.; and hoses are often left laying on the ground which may be contaminated with fertilizer, cesspools, and garden chemicals.
What protection is required for sill cocks?
A hose bib vacuum breaker should be installed on every sill cock to isolate garden hose applications thus protecting the potable water supply from contamination.
Should a Hose Bib Vacuum Breaker be used on frost-free hydrants?
Definitely, providing the device is equipped with means to permit the line to drain after the hydrant is shut-off. A “removable” type hose bib vacuum breaker could allow the hydrant to be drained, but the possibility exists that users might fail to remove it for draining purposes, thus defeating the benefit of the frost-proof hydrant feature. If the device is of the “Non-Removable” type, be sure it is equipped with means to drain the line to prevent winter freezing.
Can an Atmospheric, Anti-Siphon Vacuum Breaker be installed on a hose bib?
Theoretically yes, but practically no. An anti-siphon vacuum breaker must be elevated above the sill cock to operate properly. This would require elevated piping up to the vacuum breaker and down to the sill cock and is normally not a feasible installation. On the other hand, a hose bib vacuum breaker can be attached directly to the sill cock, without plumbing changes and at minor cost.
What is an Atmospheric Vacuum Breaker?
The most commonly used atmospheric anti-siphon vacuum breakers incorporate an atmospheric vent in combination with a check valve. Its operation depends on a supply of potable water to seal off the atmospheric vent, admitting the water to downstream equipment. If a negative pressure develops in the supply line, the loss of pressure permits the check valve to drop sealing the orifice while at the same time the vent opens admitting air to the system to break the vacuum.